Security requirements
Before a site goes live, the design has to answer four questions: who is accountable, what information is controlled, who is allowed in, and what physically stops them. Each answer has to contain certain things, some are legal minimums and some are good practice, and an auditor or a client will want the evidence. The table below separates the three.
Who this applies to
Section titled “Who this applies to”Any organisation opening a new site, changing a layout, renewing a guarding contract or preparing for a client audit. The page is also the checklist to send a security agency when you ask it to design a deployment.
It applies at three levels of intensity. A single office with a receptionist and a card reader needs the governance and information rows and a short version of the physical rows. A warehouse needs all four. A site holding Restricted material or bulk personal data needs all four plus the design sign-off described below.
The four domains
Section titled “The four domains”| Domain | Legal minimum | Good practice on top | Evidence to hold |
|---|---|---|---|
| Governance and accountability | A licensed agency under the Private Security Agencies (Regulation) Act, 2005; a contract that names security obligations; a person accountable for personal data under the DPDP Act, 2023 | A named Chief Security Officer, a written policy, a review at least once a year, and a board-level owner | Signed policy, appointment letter, review minutes, agency licence copy with expiry date |
| Information | Notice and consent for personal data, retention that ends, and cyber incident reporting within six hours under the CERT-In directions of 28 April 2022 | A three-tier classification scheme, controlled destruction, log retention for 180 days | Tier register, destruction receipts, an exported copy of logs to prove the 180 days is real |
| People | Character and antecedents verification under rule 7 of the Central Model Rules, 2020; entry-level training of 100 classroom and 60 field hours over at least 20 working days under rule 8; a Form VII certificate valid five years | Reference checks with the previous employer, an access authorisation tier per person, an exit process that recovers cards and keys, and refresher training | Form VII copy on file, training certificate, access authorisation record, exit checklist |
| Physical | Fire safety under the state fire prevention and life safety rules, and the OSHWC Code, 2020 where the premises is a factory | Perimeter and lighting standards, entry control at every staff and vehicle route, CCTV with a tested retention period, key control with a signed register | Inspection log, CCTV export test, key register, post-inspection report |
Read the table left to right. The first column is what you can be pulled up on. The third is what a serious client will ask for. The fourth is the only column that matters when the question comes eighteen months later.
What the legal minimum actually means
Section titled “What the legal minimum actually means”Three tests keep this honest.
- Is there a named instrument? “Good security practice” fails the test. “Rule 7(1) of the Central Model Rules, 2020” passes. If you cannot name the Act, rule or notification, it is good practice and should be labelled that way.
- Is the duty yours or the agency’s? The agency holds the PSARA licence. You hold the duty to satisfy yourself that the guards on your post are verified, and the duty to decide who gets access to your premises. A contract cannot move that second duty.
- Can you produce the artifact? A verified guard means a Form VII certificate you can show, dated, with the agency’s name on it. A classified document scheme means a document you can point at and a destruction receipt you can file.
Design review and sign-off
Section titled “Design review and sign-off”A zone should not open, and a restricted area should not start receiving material, until somebody has signed it off against these requirements. The sign-off is a page with four parts: the zone, the requirements it meets, the evidence attached, and the name and date of the person accepting it.
Who signs depends on the zone. A lobby is signed by the site head. A store holding Restricted material is signed by the CSO, with the agency’s supervisor countersigning the physical measures. A change to the layout that alters an entry route requires a fresh sign-off for that route, even if the rest of the zone is unchanged. The point is not ceremony: a signed page tells the next person which requirements were thought about and which were not.
How we apply it
Section titled “How we apply it”We draft the physical and people rows for your site — the post list, the access tiers, the CCTV coverage, the key register — and we produce the evidence as we go: attendance, inspection reports, incident records, and the vetting documents we hold. Your CSO signs; we do not sign on your behalf. If you want the operating scope behind that, see guarding, access control and field supervision.
Worked example
Section titled “Worked example”A business-process outsourcer takes a fourth floor in Chennai: 180 seats, two lifts, one stairwell, a shared lobby with three other tenants. The client’s audit asks for the security design.
- Governance. The Tamil Nadu licence of the agency is attached with its expiry date. The BPO’s operations head is named as accountable for personal data; the facilities manager is named as site security owner. One page, two names.
- Information. The client’s customer records sit in a system the BPO does not print. Client data is Restricted, employee data is Confidential, internal notices are Internal. One destruction vendor, monthly pickup, receipts filed.
- People. Eleven guards and two supervisors across three shifts. Each file holds a Form VII certificate dated within five years and a training certificate showing 100 classroom hours and 60 field hours. Two guards were transferred in from another state; their certificates are accepted under rule 8(5), which allows certificates issued in one state to be accepted in another.
- Physical. Card entry at the lift lobby and the stairwell door, a visitor register at reception with a photograph and host name, CCTV covering the two entries and the server room door, and a key register for the four keys that are not on cards.
The audit takes two hours instead of two weeks because the evidence was already in a folder. Nothing in that list required a new purchase.
Common failures
Section titled “Common failures”- A policy with no owner. Written by the agency, filed by the client, read by nobody.
- A CCTV retention claim nobody has tested. Export a clip from 30 days ago and try to open it. That is the test.
- Requirements that ignore the state. Licence forms, fees and inspection practice differ by state. A design copied from another state’s file carries that state’s assumptions.
Related
Section titled “Related”- Security lifecycle — where the design sits in the five stages.
- Site security plan — the document that carries these requirements into operation.
- Information classification — the tiers the information row refers to.
- Security guards — the PSARA facts behind the people row.
- Ask us for a site-level security assessment.
